Detalles de la compañía
  • Shandong Shinegoo Group

  •  [Shandong,China]
  • Tipo de Negocio:Agente , Distribuidor / mayorista , Fabricante , Servicio , Compañía de comercio
  • Principales Mercados: África , Américas , Asia , Europa del este , Europa , medio Este , norte de Europa , Europa occidental , En todo el mundo
  • Exportador:71% - 80%
  • certs:CE, OHSMS, ISO9001
  • Descripción:PVC Insulated Multicore Control,Multicore Control Wire,Multicore Control Cable
Shandong Shinegoo Group PVC Insulated Multicore Control,Multicore Control Wire,Multicore Control Cable
Inicio > Lista de Productos > Cable de control > El PVC aisló el Cable de Control > 6 core flexible pvc insulated nh-kvv fire-resistance control cable

6 core flexible pvc insulated nh-kvv fire-resistance control cable

Compartir:  
    Tipo de Pago: L/C,T/T,Money Gram,Western Union
    Incoterm: FOB,CIF
    Cantidad de pedido mínima: 100 Bag/Bags
    Plazo de entrega: 30 días
  • Mr. Ryan Li

Información básica

Tipo: Aislado

Tipo de conductor: Varado

Solicitud: Subterráneo, Calefacción

Material del conductor: Cobre

Material de la envoltura: CLORURO DE POLIVINILO

Material de aislamiento: CLORURO DE POLIVINILO

Material Shape: Round Wire

Rango de aplicación: LSOH

Proceso de dar un título: VDE, RoHS, CCC, UL, CE, ISO 9001

Marca: QIFAN

Insulation Material: PVC

Conductor Material: Copper

Rated Voltage: 450/750v

Working Temperature: 90℃

Información adicional

Paquete: Stabdard

productividad: 100000 bags

Marca: Shinegoo

transporte: Ocean,Land,Air

Lugar de origen: China

Capacidad de suministro: 100000 bags

Certificados : CCC,ISO,SGS

DDescripción

6 core flexible pvc insulated nh-kvv fire-resistance control cable

High quality PVC insulated control cable


1. Applications

1.1 Rated voltage U0/U should be 450/750 V~600/1000V

U0~Valid value of the voltage between main insulated conductor and earthing (metal shield, metal sheath of environment dielectric).

U~valid value of voltage between any two phases conductor in multicourse cable or single core cable system.

When AC. System is applied, the rated voltage of cables should be at least equal to the nominal voltage of the system. When DC. System is applied; the nominal voltage of this system should not be more than the rated voltage of the system by 1.5 times.

 

1.2 The permitting long-term operating temperature of cable conductor should be

PVC insulation: 70

Chemical Sioplascable: 90

Irradiation XLPE :105~135

 

1.3 The installing temperature of cable should not be less than 0.

Recommending permitted bending radius:

Non-armored cable: not less than the overall diameter f cable by 6 times

Shielded flexible cable: not less than the overall diameter of cable by 6 times


Our Factory

power cable factory (1)


Control Cable 450/750V Copper Coductor PVC Insulated and sheathed Flexible Control Cable

Detailed Product Description

1.Standard

The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.

2.Scope of Application

The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.

3.Type& Specification

Type

Name

Section Area(mm2)

No. of Core

Application Site

KVV

Copper Conductor,PVC Insulated and Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes

4 6

2-14

10

2-10

KVVP

Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded  Control Cable

0.75 1.0 1.5 2.5

2-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

2-14

10

2-10

KVVP2

Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable

0.75 1.0 1.5 2.5

4-10

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

7-61

10

4-10

KVV22

Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force

4 6

4-14

10

4-14

KVVR

Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable

0.5-2.5

4-61

Installation indoors where flexibility and movability are required

KVVRP

Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable

0.5 0.75 1.0

4-61

Installation indoors where flexibility shielding and movability are required

1.5 2.5

4-48

KYJV

Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes

4 6

2-14

10

2-10

KYJVP

Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

2-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

2-14

10

2-10

KYJV22

Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force

4 6

4-14

10

4-10

KYJVP2

Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

4-14

10

4-10

KYJVR

Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable

0.5-2.5

4-61

Installation indoors where flexibility and movability are required

KYJVRP

Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable

0.5 0.75 1.0

4-61

 Installation indoors where flexibility shielding and movability are required

1.5 2.5

4-48

4.Service Conditions

(1) The long-time working temperature of conductor of PVC insulated cable is 70oC

The long-time working temperature of conductor of XLPE insulated cable is 90oC

(2)  The temperature for laying the cables cannot be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D

it has the advantages of not only high mechanical strength, good ambient stress resistance, excellent electrical properties and anti-chemical corrosion, but also simple  construction, light weight and easy to use.This type of cable is applicable for connection of elecctrical equipment,  controlling, minitoring and protective system with A.C. rated voltage up to and including 450/750V.


Our Factory

factory (1)

The main feature of flame retardant control cable is hard to get fire or the continuous burning of wire is very limited when it is on fire. It applies to the place where higher demands of flame retardance.
Fire resistant control cable is not only carry the transmission of electricity under normal operating conditions,but also can operate normally for a period time when burning besides it can transmit electrical power under normal condition. It suitable for the place required resistant of fire.

factory (7)

PVC Insulated Flexible Control Cable with ISO

The main characteristics of low smoke halegen free electric wire is low smoke emmission and free of HCI gas beside the property of flame retardance. It can be used in the place with special demands of the smoke density and HCI gas when the cable is burning, such  as subway, tunnel, nuclear power station with special requirement of flame retardant, smoke density and toxicity index.


PRODUCTOS POR GRUPO : Cable de control > El PVC aisló el Cable de Control

Imagen de Producto
  • 6 core flexible pvc insulated nh-kvv fire-resistance control cable
Contactar proveedor
  • *Asunto:
  • *Mensajes:
    Su mensaje debe ser de entre 20 a 8,000 caracteres.

Sitio Web Mobile índice. Mapa del sitio


Suscríbete a nuestro boletín:
¡Obtén actualizaciones, ofertas especiales, grandes premios y descuentos!

MultiLanguage:
Copyright © 2021 Shandong Shinegoo Group Todos los derechos reservados.
Contactar Proveedor?Proveed
Ryan Li Mr. Ryan Li
¿Qué puedo hacer por ti?
Contactar Proveedor